31
NO
OK
NO
OK
BATTERIA
BATTERIA
+
-
N
12 V
Tester (
Ω
)
86
85
87
30
Tester (
Ω
)
2
1
OK
F. 28
F. 27
L I G H T I N G S Y S T E M
L I G H T I N G S Y S T E M
3.
Key switch
Disconnect key switch.
Turn key “ON”.
Connect
Tester (
Ω
)
as follows:
Terminal (+) of Tester
Orange
cable
(1)
.
Terminal (-) of Tester
Green cable
(2).
Check continuity.
•
•
•
•
•
•
Replace key switch.
4.
Light relay
Disconnect light relay.
Connect
Tester (
Ω
)
and battery
(12V)
to relay terminals, as follows:
Terminal (+) of battery
Terminal
(86)
.
Terminal (-) of battery
Terminal
(85)
.
Terminal (+) of Tester
Terminal
(87)
.
Terminal (-) of Tester
Terminal
(30)
.
Check continuity.
•
•
•
•
•
•
•
Never invert battery connections on relay terminals.
Replace light relay.
Summary of Contents for X3Motard