39
Tester (DC 20 V)
2
1
NO
OK
OK
F. 38
S I G N A L L I N G S Y S T E M
S I G N A L L I N G S Y S T E M
3.
Check voltage level
Connect
Tester (20 V DC)
as follows:
Terminal (+) of Tester
Red
cable
(1)
.
Terminal (-) of Tester
Black cable
(2).
Turn key “ON”.
Pull brake lever or press brake pedal.
Power measured must be > 12 V.
•
•
•
•
•
•
Red cable is interrupted: resume connection.
See “Wiring diagram” (P.8).
•
•
Circuit is in working order.
If black cable (ground) is interrupted,
the tail lamp will not work.