L’INDICATORE DI DIREZIONE DESTRO O SINISTRO NON FUNZIONA
1.
Turn indicator
Left hand turn indicator:
Connect
Tester (20 V DC)
to connector of light bulb coupling, as follows:
Terminal (+) of Tester
Purple
cable
(1)
.
Terminal (-) of Tester
Chassis grounding
(2).
Turn key “on”.
Operate switch to activate left turn indicators.
Right hand turn indicator:
Connect
Tester (20 V DC)
to connector of light bulb coupling, as follows:
Terminal (+) of Tester
Green cable
(3)
.
Terminal (-) of Tester
Chassis grounding
(2).
Turn
k
ey “on”.
Operate switch to activate right turn indicators.
Power measured must be > 12V in both cases.
•
•
•
•
•
•
•
•
•
•
•
•
•
Wiring between left hand switch and light bulb
coupling connector is interrupted.
Resume connection.
See “Wiring diagram” (P.8).
•
•
•
Circuit is in working order.