18
NO
OK
OK
NO
2
2
1
Tester (
Ω
)
F. 3
F. 4
1
I G N I T I O N S Y S T E M
I G N I T I O N S Y S T E M
FAULTY IGNITION
Check:
1. Fuse,
15
A
2. Battery
3. Spark
plug
4. Spark plug cap resistance
5. HV coil resistance
6. Key
switch
7. Pick-up
resistance
8. Ignition system connections
1.
Fuse 15 A
Remove relative fuse.
Connect
Tester (
Ω
)
to fuse.
Check continuity of fuse.
•
•
•
Eliminate short-circuit.
Replace fuse.
•
•
2.
Battery
Check condition of battery:
Terminal (+) of Tester
Battery (+) pole
(1)
.
Terminal (-) of Tester
Battery (-) pole
(2).
If voltage level is lower than 12.4 V, recharge using a suitable battery charger.
After charging the battery, do not use it for approximately 30 minutes; now measure voltage level again.
12.8 V or more
Battery is charged.
12,5 V
Battery needs to be recharged.
12,0 V or less
Replace battery.
Density of electrolytic solution: 1280 g/dm
3
.
•
•
•
•
•
•
•
•
•
Clean terminals.
Top up with distilled water.
Recharge or replace battery.
•
•
•
Summary of Contents for X3Motard