4. Essential safety instructions
4.1 General safety instructions
● Read the safety instructions through
carefully before commissioning.
● Ask your installer to familiarise you with the
ventilation unit and the room air control
once the installation is completed.
● Keep these instructions somewhere safe.
● Ventilation unit and room air control should
not be used as toys.
● Never operate the ventilation unit without a
filter.
● Check the filter regularly for dirt and
damage.
See Chapter 7, Cleaning,
maintenance.
● Change both air filters if the room air con-
trol filter change display appears and at the
latest, every six months. Only use original
filters.
● Filters should not be washed out as
otherwise the filter properties are lost.
● Switch the ventilation unit off immediately if
you discover damage or faults that could
endanger persons or property. Make sure
the unit cannot be switched back on until it
has been fully repaired.
● Installation is only permitted when carried
out by trained specialists.
● Electrical connections and repairs are only
permitted when carried out by trained
specialists.
● Only connect the unit to a permanent
electrical installation with 3 x 1.5 mm²
cables. Fixture for disconnecting from
mains, with at least 3 mm contact opening
needed per pole.
● The ventilation unit may only be operated
using the rated voltage and frequency
shown on the rating plate.
● Disconnect the ventilation unit from the
mains before any cleaning or maintenance
work. Switch off the mains fuse at the fuse
box. Position a visible warning notice at
the fuse box to avoid the unit being acci-
dentally switched back on.
● Modifications and alterations to the
ventilation unit are not permitted and
release the manufacturer from any
guarantee obligations and liability.
4.2 Regulations for operation with
fireplaces
Observe the DIBT (The German Institute for
Building Technology) approvals, the current
rules from the German Federation of
Chimney Sweeps (Evaluation criteria for the
joint operation of fireplaces
– domestic
ventilation
– extractor hoods) as well as other
pertinent regulations and guidelines.
The ventilation unit may only be installed
in rooms with air-ventilated fireplaces if:
● the evaluation criteria drawn up by the
responsible, regional master chimney
sweep are met,
● a parallel operation of air-ventilated
fireplaces for liquid or gaseous fuels and
the air-extracting equipment can be
prevented, or
● the extraction of exhaust gas from the air-
ventilated fireplaces is monitored by special
safety equipment. The ventilation unit or
the fireplaces must be switched off if the
equipment is triggered.