7. Troubleshooting
t
Please contact customer service if any of the actions suggested in this Section cannot be implemented.
7.1
ACX1281
Error code Messages
Action
100A
RECOVERY:
Leak detected.
• Check A/C system and unit for leaks.
1001
RECOVERY:
Service timeout.
• Check inline filters.
1002
RECOVERY:
High pressure shutdown.
• Contact customer service.
1003
RECOVERY:
Used oil bottle full.
• Empty used oil bottle.
• Reset scales.
1004
RECOVERY:
Internal refrigerant cylinder full.
• Weight limit reached. Reduce quantity of refrigerant in internal
refrigerant cylinder.
• Check scales.
1005
RECOVERY:
Used oil bottle not found.
• Check used oil bottle connection.
1009
RECOVERY:
Low pressure detected in vehicle.
• Vacuum creation.
2001
VACUUM CREATION:
High pressure detected in vehicle.
• Perform recovery process.
2002
VACUUM CREATION:
Leak detected
• Use a UV lamp to search for leaks in the vehicle air conditioning system.
2003
VACUUM CREATION:
Service timeout
• Check for clogging of service hoses.
• Check scales.
5001
RECHARGE:
Service timeout.
• Check for clogging of
ACX1281.
• Check whether the valves of the quick-release couplings are open.
5002
RECHARGE:
Insufficient refrigerant quantity.
• Perform Internal Cylinder Fill process.
• Optimum quantity of
R1234yf is 4 kg – 15.5 kg.
5003
RECHARGE:
Charging unsuccessful.
• Check whether the valves of the service quick-release couplings are open.
• Check for clogging of service hoses.
• Charge the internal refrigerant cylinder.
5004
RECHARGE:
High pressure shutdown.
• Check whether the valves on the internal refrigerant cylinder are open.
• Check for clogging of service hoses.
5005
RECHARGE:
Refrigerant cylinder full.
• Weight limit reached. Reduce quantity of refrigerant in internal
refrigerant cylinder.
• Check scales.
5006
RECHARGE:
High pressure in vehicle. Perform recovery
• Perform recovery process.
9102
FACTORY SETTING:
Not completed.
• Complete all vehicle information.
9201
SYSTEM ERROR:
No USB detected.
• Check whether USB stick is connected to USB connection.
9300
SELF-TEST UNSUCCESSFUL:
View detail.
• View details.
• Take corrective action to rectify error.
9600
PRINTER:
No paper in printer.
• Check for paper in printer.
A101
INTERNAL BOTTLE FILL:
Time elapsed.
• Check for clogging of
ACX1281.
A103
INTERNAL BOTTLE FILL:
Refrigerant cylinder full.
• Weight limit reached. Reduce quantity of refrigerant in internal
refrigerant cylinder.
• Check scales.
A104
INTERNAL BOTTLE FILL:
High pressure shutdown.
• Check whether the valves on the internal refrigerant cylinder are open.
• Check for clogging of service hoses.
A105
INTERNAL BOTTLE FILL:
Low pressure.
• Check whether the valves on the external refrigerant cylinder are open.
• Check for clogging of service hoses.
A202
SHORT FLUSHING:
Service timeout.
• Check for clogging of
ACX1281.