32 | ACX1281 | Glossary
en
10. Technical data
10.1 ACX1281
Feature
Value/Range
Dimensions H x W x D
1016 x 580 x 840mm
Weight
110kg
Operating voltage
110VAC ± 10%
Frequency
50/60Hz
Workplace emission sound pressure
level (as per EN ISO 11204)
< 70dB(A)
Refrigerant
R1234yf
Pressure sensor
0bar
Pressure sensor
0bar – 34.5bar
Pressure sensor
0bar – 10.3bar
Low-pressure gauge
-1bar – 16bar
±1% of final value
High-pressure gauge
-1bar – 40bar
±1% of final value
Capacity of internal refrigerant bottle
17.5kg
Maximum system pressure PS
20bar
Pspec
18bar
Power
900W
Operating temperature
10°C – 50°C
Optimum R1234yf filling weight
for operation
4kg – 15.5kg
t
The ACX1281 conforms to the low voltage directive (LVD).
10.2 Refrigerant identification unit
Feature
Value/Range
Refrigerant
R1234yf
Measurement accuracy
98.5% ± 0.5%
Sensor
Optical (infrared)
Operating temperature
10°C – 50°C
10.3 Electromagnetic compatibility
This product complies with the standards EN 61000-6-2 and
EN 61000-6-4.
11. Glossary
y
Recovery phase: The refrigerant is extracted from the
vehicle air conditioning system, cleaned and routed into the
internal bottle of the ACX1281. The refrigerant oil collected
in the process is drained into the used oil bottle at the
ACX1281.
y
Vacuum phase: A vacuum is generated in the vehicle air
conditioning system. Measurement of the drop in pressure
begins as soon as the vacuum has been generated.
y
Charging phase: A certain quantity of refrigerant is added to
the vehicle air conditioning system.