© MAHLE
Troubleshooting | ACX1281 | 25
ACX1281 | 25
| 25
en
Error code Messages
Action
A203
SHORT FLUSHING:
Insufficient refrigerant quantity.
• Charge the internal refrigerant cylinder.
A204
SHORT FLUSHING:
Leak detected.
• Repair vehicle air conditioning system or part being flushed.
A205
SHORT FLUSHING:
High pressure shutdown.
• Check low-pressure valve at internal refrigerant cylinder.
• Check for clogging of service hoses.
A206
SHORT FLUSHING:
High pressure in vehicle.
• Perform recovery if pressure is above 0.6 bar.
• Generate vacuum if pressure is 0.6 bar.
A208
SHORT FLUSHING:
Refrigerant cylinder full.
• Weight limit reached.
• Reduce quantity of refrigerant in internal refrigerant cylinder.
• Check scales
A209
SHORT FLUSHING:
Charging unsuccessful.
• Check for clogging of service hoses.
A302
EXTENDED FLUSHING:
Service timeout.
• Check for clogging of
ACX1281.
A303
EXTENDED FLUSHING:
Insufficient refrigerant quantity.
• Charge the internal refrigerant cylinder.
A304
EXTENDED FLUSHING:
Leak detected.
• Check for leak at part just being flushed.
A305
EXTENDED FLUSHING:
Deactivate high pressure.
• Check for clogging of
ACX1281.
A306
EXTENDED FLUSHING:
High pressure in vehicle.
• Pressure is above 0.6 bar during extraction.
• Perform recovery.
A307
EXTENDED FLUSHING:
Used oil bottle full.
• Empty used oil bottle.
• Reset scales.
A308
EXTENDED FLUSHING:
Refrigerant cylinder full.
• Weight limit reached. Reduce quantity of refrigerant in internal
refrigerant cylinder.
• Check scales.
• Replace scales.
A309
EXTENDED FLUSHING:
Charging unsuccessful.
• Check for clogging of service hoses.
A701
CALIBRATION CHECK:
Weight not attached.
• Attach calibrating weight.
A702
CALIBRATION CHECK:
Failed.
• Perform calibration again.
Summary of Contents for ACX1281
Page 1: ...MAHLE ACX1281 EN Operation manual A C Service Units...
Page 33: ...MAHLE Notes 33 en 12 Notes...
Page 34: ...MAHLE 34 ACX1281 Notes en...
Page 35: ...MAHLE Notes 35 en...