© MAHLE
16 | ACX1281 | Commissioning
en
4.3
ACX1281
m
The ACX1281 is designed for 110V, 50/60Hz. Follow the in-
formation on the ACX1281 rating plate.
1.
Set the ACX1281 on a flat, vibration-proof surface.
2.
Actuate the caster brake to stop the ACX1281 from rolling.
3.
Connect the power supply cable to the power supply.
4.
Switch on the main switch.
@
The self-test starts automatically. The menu appears fol-
lowing successful completion of the self-test.
@
The fan is switched on.
t
The fan runs while the ACX1281 is switched on.
4.3.1 Setting language
1.
Select "
Settings
>>
General settings
>>
Language
".
2.
Select language with
.
3.
Store entries with
O
.
4.3.2 Setting date and time
1.
Select "
Settings
>>
General settings
>>
Date and Time
".
2.
Alter values with input keys.
3.
Move to next value with
.
4.
Store entries and return with
O
.
4.3.3 Setting workshop data
1.
Select "
Settings
>>
General settings
>>
Workshop Details
".
t
A maximum of 30 characters can be entered.
t
Delete values previously entered with <
C
>.
2.
Alter values with input keys.
3.
Store entries and return with
O
.
4.3.4 Activating / deactivating printer, workshop
info, buzzer, operator list, daily leak test
1.
Select "
Settings
>>
General settings
>>
System settings
".
2.
Select the menu item printer, workshop info, buzzer, opera-
tor list or daily leak test with
.
3.
Activate/deactivate with
.
4.
Store entries and return with
O
.
Activation
Description
Printer
Printer ready for operation.
Operator list
An operator must be selected or a new operator en-
tered prior to each A/C service.
Workshop info
Workshop data are printed out together with the
service print-out
Buzzer
An audible alarm additionally soundsin the event of
error messages.
Daily self leak test Automatic leak test process that occurs every 24
hours.
4.3.5 Maximum service data records
t
The ACX1281 stores the service data sets. The factory limit
value setting for the maximum number of data sets is 400.
t
If the number of stored data sets exceeds the limit, service
can no longer be performed. Further service work is only
possible after transferring the data sets to a USB stick.
1.
Select "
Settings
>>
General settings
>>
Maximum service data records
".
2.
Alter values with input keys.
3.
Store entries and return with
O
.