© MAHLE
Important notes | ACX1281 | 7
ACX1281 | 7
| 7
en
y
Position the ACX1281 on all four wheels on a flat, vibration-
proof surface so that proper operation of the scales is guar-
anteed.
y
The ACX1281 can be secured in position by locking the caster
brake.
y
The ACX1281 must always be transported in its operating
position. Never lay the ACX1281 on its side, as oil could then
escape from the vacuum pump or the built in compressor
could be damaged.
y
There are no additional safety systems for protecting the
ACX1281 against damage resulting from natural catastrophes.
y
Never remove any components from inside the ACX1281
except for maintenance or repair purposes.
y
Follow the pertinent legal regulations or directives to ensure
safe handling of pressurized devices.
y
We recommend calibrating the scales at least once per year.
Contact customer service for calibration of the scales.
y
The ACX1281 must be subjected to regular maintenance by
service personnel or authorized agents to ensure the safety
of the unit.
y
Disconnect power before performing any maintenance or
service to unit.
y
Never perform any maintenance work which is not expressly
recommended in this manual. Contact customer service if
components have to be replaced other than in the course of
maintenance work.
y
ACX1281 must be connected to a properly grounded electri-
cal connection.
y
If there is damage to the ACX1281, terminate usage immedi-
ately and contact customer service.
y
The service hoses and service quick-release couplings must
be regularly checked for wear and replaced if damaged.
y
The ACX1281 must be operated in an environment cor-
responding to the directive BGR 157 with respect to the
exchange of air.
y
Observe local laws or directives as to ensure the safety of the
pressurized device.
y
For safety reasons it is advisable to use a residual current
operated circuit breaker (rccb) with the following specifica-
tions:
Parameters
Specification
Rated voltage
110 VAC ± 10%
Rated frequency
50/60Hz
Rated current
10A
Rated tripping current
30mA
Tripping switch
C
2.4.2 Refrigerant identification unit
y
Inspect the outside diameter of the white sample filter element
before and after each use of this unit. As soon as red spots
begin to appear on any portion of the white element outside
diameter, the filter requires replacement. Failure to replace the
filter when so indicated may result in damage to the identifica-
tion unit (out of warranty).
y
Never use a test hose other than those approved for use with
the Identifier.
y
Never connect the Identifier to any refrigerant source that
exceeds 300 psi pressure.