Fig. 9.1: Removing the case
2.1 - Power supply
Should any hardware modification be performed, remove the
electronics from the case as shown in figure 9.1.
115/230 V AC:
The instruments with 115/230 V AC power, are
shipped from the factory for 230 V AC (USA market 115 V AC),
see figure 9.2. To change supply voltage to 115 V AC, set
jumpers as indicated in figure 9.3 (see table 1). The wiring label
should be modified to match new setups.
24/48 V AC:
The instruments with 24/48 V AC power supply,
are shipped from the factory for 24 V AC, see figure 9.3 To
change supply voltage to 48 V AC, set jumpers as indicated in
figure 9.2 (see table 1). The wiring label should be modified to
match new setups.
10-30V DC:
The instruments for 10-30V DC power supply are
prepared to withstand any voltage between 10 and 30V without
need of wiring changes.
Fig. 9.2. Supply voltage 230 V or 48 V AC
Fig. 9.3. Supply voltage 115 V or 24 V AC
Table 1. Jumper settings