16
Magtrol AN 2000 C
Instruction Manual
From the run mode, press
ENTER
to get access to the programming mode (the display
shows -Pro-). Press two times the
key to go to the entry stage of the display
configuration module, represented in fig. 16.1. This module provides four menus:
scaling, balanced filter, damping filter and round. Press
ENTER
to access to the first
menu (SCAL) and press repeatedly the
key if you want to shift around the
different menus (See next pages for instructions on each menu).
(From 2 CndSP stage) skips over this module and advances to the next one
or to the -Pro- stage.
ESC
Exits from the programming routines and brings the instrument to the run
mode.
3./ Scaling the indicator.
After deciding the values for INPUT and DISPLAY and the decimal point position, we are ready to enter in the display
configuration module (2 CndSP) to effectively scale the meter. The scaling procedure is completed with digital filters and display
rounding.
[16.1] Display configuration
B
A
TARE
HOLD
LIMIT
MAX
MIN
DATA
DSP2
INP2
FLT
STORE
DSP1
INP1
2
1
4
3
TARE
RESET
LIMIT
MAX/MIN
ENTER
ESC
DATA
PROG
TEACH
PRG
RUN
B
A
TARE
HOLD
LIMIT
MAX
MIN
DATA
DSP2
INP2
FLT
STORE
DSP1
INP1
2
1
4
3
TARE
RESET
LIMIT
MAX/MIN
ENTER
ESC
DATA
PROG
TEACH
PRG
RUN
B
A
TARE
HOLD
LIMIT
MAX
MIN
DATA
DSP2
INP2
FLT
STORE
DSP1
INP1
2
1
4
3
TARE
RESET
LIMIT
MAX/MIN
ENTER
ESC
DATA
PROG
TEACH
PRG
RUN
B
A
TARE
HOLD
LIMIT
MAX
MIN
DATA
DSP2
INP2
FLT
STORE
DSP1
INP1
2
1
4
3
TARE
RESET
LIMIT
MAX/MIN
ENTER
ESC
DATA
PROG
TEACH
PRG
RUN
B
A
TARE
HOLD
LIMIT
MAX
MIN
DATA
DSP2
INP2
FLT
STORE
DSP1
INP1
2
1
4
3
TARE
RESET
LIMIT
MAX/MIN
ENTER
ESC
DATA
PROG
TEACH
PRG
RUN
MENU 2A
SCALING
MENU 2B
BALANCED FILTER
MENU 2B
DAMPING FILTER
MENU 2AB
ROUND FILTER
ENTER