37
Magtrol AN 2000 C
Instruction Manual
The value parameter of the delay / hysteresis parameter
(3AB ModE) indicates how long will the relay / opt be
activated when the peak is reached. (Except in latch mode).
The relay / opto output will be activated when the display
stops increasing (once reached the value of setpoint2) during
a number of evaluations programmable by the user and
between 0 and 99.
The selection of the number of evaluations appears at the
continuation of the configuration of setpoint2 after
introducing “6” or “7” in the fourth digit.
RS232
Compatible with ModBus-RTU protocol (see ModBus manual).
RS485
This output can be used to print several data on a panel
printer (see logic functions page 29).
Once chosen the print function, the next step presents
on / off to activate the function TIME which prints the time
and date.
Compatible with ModBus-RTU protocol (see ModBus manual).
OUTPUT SERIE
The function 10 (write) is now available in the ModBus
protocol, whereas the 01 and 0F are no longer available.
New functions:
Command
Function
Data Request
Z
Totalizer value
B
Batch Counter value
Orders
z
Reset Totalizer
x
Reset
Batch Counter
a#
Activate setpoint nº#
d#
Deactivate
setpoint nº#
Parameter Modification
S#
Change the value of setpoint
nº# without saving it
ANALOGICAL
See remote inputs, page 29.
BCD
See remote inputs, page 28 and 29.