Appendix F - Error Codes
DynaPro Go| Handheld PIN Pad Device with MSR/Contact/Contactless | Programmer’s Manual (COMMANDS)
Page 171 of 247 (
D998200136-31
)
Code Calculated
Cn where n = sum of the
following
Description
+8
MSR Key Loader CA Certificate not loaded
+16
Device Certificate does not exist
+32
TLS Certificate does not exist
F.4
Device Offline K Codes
Table 4-108 - "K" Error Codes
Code Displayed
Description
K15
No MSR Key Loader Certificate or MSR Key installed
No PIN Key Loader Certificate or PIN Key installed
K13
No MSR Key Loader Certificate or MSR Key installed
No PIN key installed (or exhausted)
K12
No MSR Key Loader Certificate or MSR Key installed
K7
No PIN Key Loader Certificate or PIN Key installed
No MSR Key installed (or exhausted)
K5
No MSR Key installed (or exhausted)
No PIN Key installed (or exhausted)
K4
No MSR Key installed (or exhausted)
K3
No PIN Key Loader Certificate or PIN Key installed
K1
No PIN Key installed (or exhausted)
F.5
Device Offline A Codes
Table 4-109 - "A" Error Codes
Code Displayed
Description
A00
Device awaiting authentication