3.0 Setup
Default Settings:
Info:
Refer to page 6, 3.2.1 FAVS button for information on how to
change a FAVS menu item.
FAVS: F1 Search Watts -
Search Watts is the F1 default (FAVS #1). Refer
to page 20 for SETUP 02A Search Watts on how to adjust the Search Watt
setting.
FAVS: F2 LBCO Setting -
LBCO (Low Battery CutOut) is the F2 default
(FAVS #2). Refer to page 20 for SETUP 02B LBCO setting on how to adjust
the LBCO setting.
FAVS: F3 AC Input Amps -
AC Input Amps is the F3 default (FAVS #3).
Refer to page 24 for SETUP 03A AC Input Amps on how to adjust the AC
Input Amps
FAVS: F4 Battery Type -
Battery Type is the F4 default (FAVS #4). Refer to
page 24 for SETUP 03B Battery Type on how to set the Battery Type.
FAVS: F5 Gen Control -
Gen Control is the F5 default (FAVS #5). Refer to
page 11 for CTRL 03 Gen Control on how to operate the Gen Control func-
tion.
F1 Search Watts
5 Watts
Rotary
SELECT Knob
LCD
Display
FAVS
Button
Figure 3-3, FAVS Button
Press to edit
setting
press
FAVS
rotate to
desired
selection :
F1 Search Watts
5 Watts
T op line show s current
F AVS m enu and position
in F AVS m enu
Bottom line show s current
setting. Push Select to edit
current setting
T o select the next
F AVS item
F5 Gen Control
OFF
F2 LBCO Settting
10.0 VDC
F3 AC Input
Amps = 30A
F4 Battery Type
Flooded
F1 Search Watts
5 Watts
The FAVS button has
fi
ve default menu items stored from the factory and
may be changed by accessing menu items using the METER, SETUP or TECH
button.