53
Control unit MGC
Description of menus and parameters
Operational view > Main menu > Service > Gate HW
Parameter
Description
Target position right Check and adjust the angle of rotation of the blocking element.
Observe the position of the mechanical end stops. If necessary, the
mechanical end stops must be reset.
Setting range
›
0° … +120°
Factory setting
›
90°
Homing direction
(Homing target)
Select the direction of rotation for the blocking element during homing.
The swing door performs a homing after each switch on. In the case of
homing, the blocking element is first moved to the "Open" position and then
to the "Closed" position (home position).
If you change the setting for the "Homing direction" parameter, the
parameters "Align home position", "Target position left" and "Target position
right" are reset to the factory setting.
Options
›
Clockwise (CW)
›
Counterclockwise (CWW)
Factory setting
›
Clockwise (CW)
Table 22:
Gate HW