14
Control unit MGC
Digital inputs, digital outputs and relay outputs
Function
Description
Locking (internal
use)
Connection of the locking via the brake booster
The locking via the brake booster is connected to this output in the factory.
Table 6:
Function digital outputs and relay outputs
2.3
Illumination
You can order the swing door with the following optional illuminations:
›
Hood illumination
›
Wing illumination
›
Floor illumination
The hood illumination and the wing illumination signal the following events:
Colour
Description
Red
›
Pedestrian gate closing.
Flashing red
›
An obstacle has been detected.
›
Vandalism detected.
›
There is an error.
Green
›
Pedestrian gate is closed.
›
Pedestrian gate is open.
›
Pedestrian gate opens.
Flashing yellow
›
The pedestrian gate performs homing.
›
The target positions "Closed", "Left" and "Right" are aligned.
Table 7:
Description signalling illumination