4.2.4.3 Non-Interlocked Functions for EM Systems
Unlike interlocked settings, non-interlocked settings allow the two adjacent pushbuttons
to be used simultaneously.
NOTE:
If any of the pushbuttons are set to turn on an LED for toggle operation, the
corresponding receiver output cannot be set for toggle operation as well. If it is, then
the function will not operate correctly. The toggle operation can only be set in either
the transmitter or the receiver, not both.
Dip
Settings
Function Descriptions
# of Relays
Used
0100010
Closed/Closed Relay Brake
3
0100011
Opened/Closed Relay Brake
4
Dip
Settings
Function Descriptions
(left button/right button)
# of Relays
Used
1000
Normal/Normal
2
1001
Toggled/Normal
2
1010
Normal/Toggled
2
1011
Toggled/Toggled
2
1100
Toggled (shuts off when E-Stop is pressed)/Normal
2
1101
Normal/Toggled (shuts off when E-Stop is pressed)
2
1110
Toggled/Toggled (both shut off when E-Stop is pressed)
2