Flex EM/EX HazLoc System Instruction Manual
June 2019
Page 26 of 62
NOTE:
PB8 is not available on 8-button A/B transmitters
PB12 is not available on 12-button A/B transmitters
PB7…PB12
→
Pushbutton number
Normal
→
Normal momentary contact
A/1&2…D/3&4
→
A/B Selector type with designated LED Display (LED 1&2 or LED 3&4)
4.1.2.3 Inline Pushbutton Configuration (Transmitter Toggle)
(EX Transmitter Only)
The pushbutton arrangement for inline pushbutton setup starts from top to bottom and
then from the right column to the left column
(see Fig. 10)
. To set inline pushbutton
configuration, see JP4 and JP5 jumper settings in
Section 4.2.5 on page 43
. With
inline pushbutton configuration, PB1 and PB2 still correspond to output relay K1 - K4;
PB3 and PB4 correspond to relay K5 - K8, etc.
Fig. 10
NOTE:
These settings are not available on EM systems
DIP
PB7
PB8*
PB9
PB10
PB11
PB12*
01011011
Normal
Normal
Normal
Normal
A/1&2
A/3&4
01011100
Normal
Normal
Normal
Normal
A/1&2
B/3&4
01011101
Normal
Normal
Normal
Normal
A/1&2
C/3&4
01011110
Normal
Normal
Normal
Normal
A/1&2
D/3&4
01011111
Normal
Normal
Normal
Normal
B/1&2
B/3&4
01100000
Normal
Normal
Normal
Normal
B/1&2
C/3&4
01100001
Normal
Normal
Normal
Normal
B/1&2
D/3&4
01100010
Normal
Normal
Normal
Normal
C/1&2
C/3&4
01100011
Normal
Normal
Normal
Normal
C/1&2
D/3&4
01100100
Normal
Normal
Normal
Normal
D/1&2
D/3&4