Flex EM/EX HazLoc System Instruction Manual
June 2019
Page 28 of 62
4.1.2.4 Inline Pushbutton Configuration (A/B Selector) (EX Transmitter
Only)
There are four (4) different types of A/B selector sequences available on the Flex
system. Choose the one that is most suitable for your application.
Type-A selector sequence: A+B
→
A
→
B
→
A+B…
Type-B selector sequence: Off
→
A
→
B
→
Off
→
A
→
B…
Type-C selector sequence: A
→
B
→
A+B
→
A
→
B
→
A+B…
Type-D selector sequence: Off
→
A
→
B
→
A+B
→
Off
→
A
→
B
→
A+B…
NOTE:
These settings are not available on EM systems
8-Button Transmitter:
NOTE:
PB8 is not available on A/B transmitters
PB5…PB8
→
Pushbutton number
Normal
→
Normal momentary contact
LED 1…LED 4
→
Transmitter toggled with designated LED Display
DIP
PB5
PB6
PB7
PB8*
01110011
Normal
Normal
A/1&2
Normal
01110100
Normal
Normal
B/1&2
Normal
01110101
Normal
Normal
C/1&2
Normal
01110110
Normal
Normal
D/1&2
Normal
00110011
Normal
Normal
Normal
A/3&4
00110100
Normal
Normal
Normal
B/3&4
00110101
Normal
Normal
Normal
C/3&4
00110110
Normal
Normal
Normal
D/3&4
01110111
Normal
Normal
A/1&2
A/3&4
01111000
Normal
Normal
A/1&2
B/3&4
01111001
Normal
Normal
A/1&2
C/3&4
01111010
Normal
Normal
A/1&2
D/3&4
01111011
Normal
Normal
B/1&2
B/3&4
01111100
Normal
Normal
B/1&2
C/3&4
01111101
Normal
Normal
B/1&2
D/3&4
01111110
Normal
Normal
C/1&2
C/3&4
01111111
Normal
Normal
C/1&2
D/3&4
10000000
Normal
Normal
D/1&2
D/3&4