Flex EM/EX HazLoc System Instruction Manual
June 2019
Page 23 of 62
12-Button Transmitter:
NOTE:
PB12 is not available on A/B transmitters
PB7…PB12
→
Pushbutton number
Normal
→
Normal momentary contact
LED 1…LED 4
→
Transmitter toggled with designated LED Display
4.1.2.2 Standard Pushbutton Configuration (A/B Selector)
(EX Transmitter Only)
There are four (4) different types of A/B selector sequences available on the Flex
system. Choose the one that is most suitable for your application.
Type-A selector sequence: A+B
→
A
→
B
→
A+B…
Type-B selector sequence: Off
→
A
→
B
→
Off
→
A
→
B…
Type-C selector sequence: A
→
B
→
A+B
→
A
→
B
→
A+B…
Type-D selector sequence: Off
→
A
→
B
→
A+B
→
Off
→
A
→
B
→
A+B…
NOTE:
These settings are not available on EM systems
DIP
PB7
PB8
PB9
PB10
PB11
PB12*
00000000
Normal
Normal
Normal
Normal
Normal
Normal
00001001
Normal
Normal
Normal
LED 4
Normal
Normal
00001010
Normal
Normal
LED 3
LED 4
Normal
Normal
00001011
Normal
LED 2
LED 3
LED 4
Normal
Normal
00001100
LED 1
LED 2
LED 3
LED 4
Normal
Normal
00001101
Normal
Normal
Normal
Normal
Normal
LED 4
00001110
Normal
Normal
Normal
Normal
LED 3
LED 4
00001111
Normal
Normal
Normal
LED 2
LED 3
LED 4
00010000
Normal
Normal
LED 1
LED 2
LED 3
LED 4