4.2 Receiver Unit
4.2.1
System Channel Settings
Fig. 11
Even though the Flex system is equipped with an automatic channel scanning receiver,
the user can also set the receiver channel manually.
See Section 4.2.3 on page 38
for
information on using the automatic channel scanning receiver.
Set the receiver channel by adjusting the channel dipswitch located on the receiver
module
(see Fig. 11)
. Only the first six (6) positions are used for channel programming
(see Fig. 12)
. The system channels table in
Section 5 on page 47
illustrates which
dipswitch setting corresponds to which channel. Once the receiver channel is altered,
be sure to change the transmitter channel as well. The channel on both the transmitter
and receiver must be identical in order for the system to work. To change the transmitter
channel,
see Section 4.1.1 on page 21
.
Example:
Fig. 12
The above dipswitch setting
“1 0 0 1 0 0”
corresponds to “channel 36” in the system channels table in
Section 5 on page 47
.
INT
EXT
1
2
3
5
6
8
4
7