4
(E)
3. Operation
3-1. Name of each part
ALM
LEVEL
SPEED
MJ100
OFF OFF
ON OFF
OFF ON
ON ON
ABS
1
1
234
5
6
7
8
9
1
0
2
3
4
5
6
7
8
9
10
MODE
OFF
ON
b
ABS lamp
a
MODE switch
c
POS. lamp
d
ALARM lamp
e
Output connector
g
Head cable connector
f
Reference point connector
Fig. 3-1
a
Mode
switch
Sets the reference point, A/B phase direction,
and resolution.
b
ABS
lamp
Lights when the reference point input signal
is ON.
c
POS.
lamp
Used while setting the reference point.
d
ALARM
lamp
Lights when an alarm is generated. LEVEL
indicates a level alarm for the input signal,
while SPEED indicates an excess speed alarm.
e
Output
connector
Th
is connector is used to input power and to
output each signal.
f
Reference point connector
Connector used for reference point signal
input.
g
Head cable connector
Connector for head unit signal input.