46
/
48
8.6
PLC Link Setup Commands (Ethernet Only)
Command
Description
NIP= / NIP=?
Command/Return format
IP address of MG80-SC
NIP=
③
③
= IP address in IPv4 format (e.g. 192.168.0.100)
NMS= / NMS=?
Command/Return format
Subnet mask of MG80-SC
NMS=
③
③
= Subnet mask in IPv4 format (e.g. 255.255.255.0)
LPN=
③
/ LPN=?
Command/Return format
Port number to be used by the PLC link
LPN=
③
③
= 0 to 65535 (24000 is prohibited)
LMD=
③
/ LMD=?
Command/Return format
PLC link use mode
LMD=
③
③
= 0: Do not use PLC link
1: Use PLC link
LPC1= / LPC1=?
Command/Return format
PLC link protocol 1 (protocol)
LPC1=
③
③
= 0: MC protocol/1C frame format 4
1: MC protocol/3C frame format 4
2: MC protocol/1E frame
3: MC protocol/3E frame (Q/L)
4: MC protocol/3E frame (iQ-R)
5: C mode command
6: FINS command
7: Upper link
LPC2= / LPC2=?
Command/Return format
PLC link protocol 2 (format)
LPC2=
③
③
= 0: ASCII
1: Binary
LPC3= / LPC3=?
Command/Return format
PLC link protocol 3 (interface)
LPC3=
③
③
= 0: RS-232C
1: TCP/IP
2: UDP/IP
RIP=
③
/ RIP=?
Command/Return format
PLC side IP address
RIP=
③
③
= IP address in IPv4 format (e.g. 192.168.0.100)