Measurement Data Output
The measurement data is output to RS-232C based on the timing of the RS trigger input or the internal periodic
timer. It is not output during parameter setup.
The timing of the measurement data output should take into account the RS-232C baud rate. If the next trigger
occurs during the measurement data output, incorrect data may be output.
6.2.9
I/O Connector
In addition to the RS-232C command, data can be output and the operations performed through the I/O connector.
I/O Connector Pin
Assignment
No.
I/O
Function name
Description
1
I
Reset input
All the measurement axes are reset.
2
I
RS-232C trigger input
The measurement data of all the axes is latched and the data is
output.
3
I
Pause input
While the input signal is supplied, pause all measurement axes.
4
I
Start/latch input
When the start function is selected as the input setting: the peak
value updating starts on all measurement axes as soon as the input
signal is supplied;
when the latch function is selected: while the input signal is
supplied, latch all measurement axes.
Set the function by the STTERM command.
5
―
Input Common
Input signal common pin
6
O
Alarm
Output when an alarm occurs in the system.
7
―
Output Common
Output signal common pin