35
/
48
⑤
Specifies the starting address on the device assigned to the control flag by the PLC link*.
Refer to the data structure of the control flag to ensure that the area does not overlap with other areas.
⑥
Specifies the starting addresses on the device assigned to the setup parameters by the PLC link*.
The setup parameters are set for each axis number (counter module ID).
Refer to the data structure to ensure that the area does not overlap with other areas.
⑦
Specifies the starting address on the device assigned to the measurement data by the PLC link*.
Refer to the data structure of the measurement data to ensure that the area does not overlap with other areas.
* The PLC link assigns the data exchanged with the MG80-SC to the PLC device.
Mitsubishi Electric Corporation PLC: Data register (D)
OMRON Corporation PLC : Data Memory (DM)
Keyence Corporation PLC : Data Memory (DM)
⑧
Specifies the settings when “FINS command” is selected in
④
.
・
SA1: Source FINS node address
For UDP, set the node address of the MG80-SC.
Specify the low-order byte of the IP address of the MG80-SC.
For TCP, no setting is required.
・
DA1: Destination FINS node address
For UDP, set the node address of the PLC.
For TCP, no setting is required.
・
DNA: Destination FINS network address
Specify the network address of the PLC and MG80-SC.
The PLC and MG80-SC must be on the same network.
If there is only one network on the PLC side, it is usually set to 0.
⑨
Specifies the settings when “C mode command” is selected in
④
.
Specify the Unit No. of the connection destination.
⑩
Sends the settings made on the PLC Link Setting window to the MG80-SC.
If the reference point setting is changed, the power must be turned off and on again.
Do not turn off the power of the MG80-SC while saving the settings.
After sending the settings, press the [Disconnect] button and [Connect] button to reconnect to the MG80-SC and
make sure that the set values are applied correctly.