On time (Ont)
In pnt mode, the time the welding is active will be set. During this time, the welding will continue and the welding
will stop at the end of the period.
Setting range: 0 - 10 sec.
Off Time (OFt)
Stand-by time during welding is adjusted in pnt mode. During the set time, the welding will stop and restart at the
end of the period.
Setting range: 0 - 10 sec
.
Standby Mode (SLC)
When the machine is not used after the time set for sleep mode, it goes into standby mode. This prevents unnecessary
energy consumption.
Setting range: On - Off
Soft Start (SoS)
When the source is first started, the wire speed rises slowly from the lowest speed until reaching the set speed. By this
means, backlash and spatters are prevented at the beginning of the welding process.
Setting range: On - Off
Cooling Time (Cot)
After the use of machine has been completed, the water-cooling unit continues to operate for the set period of time.
This prevents hot water from damaging the torch.
Setting range: 4 - 10 min.