2.3 Mains Plug Connection
2.4. Welding Connections
• No plug has been connected to the mains cable since there may different types of
outlets available in plants, construction sites and workshops. A suitable plug
must be connected by a qualified technican. Make sure that the grounding cable
marked with and a yellow/green color is present.
• AFTER CONNECTING THE PLUG TO THE CABLE, DO NOT ATTACH IT TO THE OUTLET AT
THIS STAGE.
• Place the wire feed unit on the rotating equipment.
• Connect the blue gas hose to the gas outlet on the front of the power supply.
• Connect the control cable of the wire feed unit to the wire feeder connector on the power supply and lower the lock.
• Connect the welding current plug to the welding current plug socket on the power supply and secure it by turning to the right.
Figure 5: Power Plug Connection
For your safety, never use the mains cord of the machine without a plug.
2.4.1 Wire Feed Unit Connections
• Grounding cable sockets with different inductance values allow welding with lower spatter in a wide current range. Socket for low current and
small wire diameters socket, for high current and large wire diameters or socket should be preferred.
• Connect the grounding pliers wire to one of the grounding wire sockets on the machine and tighten by turning it to the right.
• To improve the welding quality, firmly connect the grounding pliers to the workpiece as close as possible to the welding area.
Make sure the connections are tight and secure. Loose or incorrect connections may cause overheating or gas leakage.
2.4.2 Grounding Pliers Connections
Figure 6 : Intermediate Hose Pack and Grounding Pliers
Connections for RS 350 / 450 / 550 M PRO
Figure 7 : Intermediate Hose Pack and Grounding Pliers
Connections for RS 350 / 450 / 550 MW PRO
Installation