1.3 Product Label
Three Phase Transformer Rectifier
Duty Cycle
X
Horizontal Characteristic
Open Circuit Voltage
U0
Rated Welding Current
I2
Direct Current
Mains Voltage and Frequency
U1
Protection Class
IP21S
MIG/MAG Welding
Rated Welding Voltage
U2
Rated Power
S1
Mains Input 3-Phase Alternating Current
Rated Mains Current
I1
Suitable for Operation at Hazardous Environments
As defined in the standard EN 60974-1, the duty cycle rate includes a time period of 10 minutes. For example, if a machine specified as 250A
at %60 is to be operated at 250A, the machine can weld without interruption in the first 6 minutes of the 10 minutes period (zone 1). However, the
following 4 minutes should be kept idle for the machine cool down (zone 2).