EN
www.magmaweld.com
19
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
RS 350 M / MW PRO - RS 450 M / MW PRO - RS 550 M / MW PRO
Figure 8 : RS 350 / 450 / 550 M PRO
Intermediate Package Connections with Connectors
Figure 9 : RS 350 / 450 / 550 MW PRO
Intermediate Package Connections with Connectors
Dirty and lime (hard) waters reduce the operating life of the torch and the pump.
If the coolant is below the minimum value, there is a possibility of damage and malfunction for the pump and torch.
• Water cooling unit is a closed-circuit system consisting of a radiator, fan, pump and water tank used for cooling the torch.
If your machine has a water-cooling unit:
• Connect the cold (blue) water hose to the cold-water outlet on the water-cooling system and the hot (red) water hose to the hot water inlet on the
water cooling system.
• Remove the water tank cover and fill the water tank with lime-free water containing antifreeze appropriate for the working environment
temperature. The coolant must be within the minimum and maximum values shown on the front panel of the unit.
• It is not suitable to use the water-cooling units with welding machines other than manufactured by Magma Mekatronik Makine ve Sanayi Ticaret A.Ş.
Water cooling units cannot be operated with external supply.
• For easy transport on machines with hose package of 10 meters or longer, the wire feed unit and the hose package have been designed to be
detachable. Both ends of the long hose packages are the same and the connections on the machine front must be made with the connectors and
sockets on the back of the wire feeder.
• If your machine’s hose package is 10 meters or longer, connect the wire feed unit with the hose package as follows.
2.4.3 Water Cooling Unit
2.4.4 Connection of Long Interim Packages
Installation