EN
www.magmaweld.com
11
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
RS 350 M / MW PRO - RS 450 M / MW PRO - RS 550 M / MW PRO
The electrical current passing through any conductor generates zonal electric and magnetic fields (EMF).
All welders must follow the following procedures to minimize the risk of exposure to EMF from the
welding circuit;
• In the name of reducing the magnetic field, the welding cables must be assembled and secured as far
as possible with the joining materials (tape, cable ties etc.).
• The welder’s/worker’s body and head should be kept as far away from the welding machine and
cables as possible,
• Welding and electric cables should not be wrapped around the body of the machine in any way,
• The body of the machine should not get caught between the welding cables. The source cables must
be kept away from the body of the machine, both being placed side by side,
• The return cable must be connected to the workpiece as close as possible to the welded area,
• The welding machine should not rest against the power unit, ensconce on it and not work too close
to it,
• Welding work should not be performed when carrying the welding wire supply unit or welding
power unit.
EMF may also disrupt the operation of medical implants (materials placed inside the body), such as
pacemakers. Protective measures should be taken for people who carry medical implants. For example,
access limitation may be imposed for passers-by, or individual risk assessments may be conducted for
welders. Risk assessment should be conducted and recommendations should be made by a medical
professional for users who carry medical implants.
• Do not expose the machine to rain, prevent the machine from splashing water or pressurized steam.
• Choose the welding method and welding machine for the welding work you are to perform.
• Select the welding current and/or voltage to match the material and thickness you are going to weld.
• If you have to wait for a long time before you start your welding work, turn off the machine after the
fan has cooled it down. Our machines (our products) with smart fan control will turn off on their own.
• This device is not domestic waste. It must be directed to recycling within the framework of the
European Union directive and national laws.
• Obtain information from your dealer and authorized persons about the waste management of your
used machines.
Arc Welding May Cause
Electromagnetic
Field (EMF)
Protection
Energy Efficiency
Waste Procedure
Safety Precautions