EN
www.magmaweld.com
Monotig 160ip
15
USER MANUAL | KULLANIM KILAVUZU
2.3 Connections For TIG Welding
• Switch the machine to the position “OFF” “0” and insert the plug into the socket.
• SWITCH ON the machine via power switch
(2)
. Observe that the switch itself and the led displays in the front panel lits, also you should hear the
sound of the cooler fan.
• Secure the gas cylinder
(11)
to a wall by a chain. To operate safety and get best results, use approved regulators.
• Open the gas cylinder valve
(13)
few times in order to blow out any possible dirt or particles.
• Connect the gas regulator to the cylinder, make sure that the threading of the gas outlet of the cylinder and the nut of the regulator match.
• Connect one end of gas hose
(14)
to the gas regulator
(12)
and connect the other end to the gas supply inlet
(3)
. Open the gas cylinder valve
(13)
.
• Set the gas quantity with the pressure adjustment valve
(15)
.
• Make sure that there are no gas leakages from any connection.
2.3.1 Mains Connection and Switching ON
2.3.2 Gas Connections
Before plugging your machine to the electrical line, check the line voltage.
Figure 2: Gas and Mains Connections
Figure 3: Gas Cylinder - Regulator - Hose Connections
Diameter of
Electrode (mm)
Diameter of
Nozzle (mm)
Welding
Current (ADC)
Gas Debit
(lt/dak)
1.0
1.6
6.3
9.5
30-70
30-150
6-8
6-8
Installation