Monotig 160ip
EN
www.magmaweld.com
22
USER MANUAL | KULLANIM KILAVUZU
When the torch trigger is pushed, main current starts immediately and goes on as long as the torch trigger is kept pushed. Welding goes on during spot
welding time. After spot welding time is over, current stops immediately.
For using welding modes (2 Stroke - 4 Stroke - Spot Welding) in Flat DC mode, select Flat DC mode by button
(13)
, its LED (
14)
will be on. In this
mode, only main current (19) is used and it is simply adjusted by the multifunctional knob
(1)
.
For using welding modes (2 Stroke - 4 Stroke - Spot Welding) in Pulse DC mode, select Pulse DC mode by button
(13)
, its LED
(15)
will be on. In this
case, main current
(19)
, base current
(20)
and the Pulse frequency
(21)
should be adjusted by the multifunction knob
(1)
. welding current changes
between main current and base current in the adjusted Pulse frequency.
Spot TIG Trigger
DC / Pulse DC
4 Stroke TIG Trigger
PrG
: Initial Gas Time
I
: Welding Current
PoG
: Final Gas Time
Push the welding mode selection button
(5)
until the MMA LED
(6)
lights.
In this mode, only the main current LED
(19)
lights and welding current can be adjusted by the main knob. All other functions are inactive.
When the machine overheats, an error message
(Err)
appears on multi functional digital display
(2)
and the LED
(26)
flashes.
In this case, wait for the machine to cool down and the error message to disappear, then you can start welding safely again.
3.3.3 MMA Welding Process
3.3.4 Error Message
Operation