10 MAGICFX FLAMEBLAZER
®
—
User and Installation Manual
1.6
ARM CONTROL
NOTICE
The FLAMEBLAZER cannot be operated without connection to an
ARM CONTROLLER in an ARM SYSTEM.
The FLAMEBLA
ZER is configured for safety control with an ARM SYSTEM. The
FLAMEBLAZER cannot be operated without the safety signal from the control unit of
the ARM SYSTEM: The ARM CONTROLLER. When there’s no signal, the internal relief
valve opens. The system depressurises immediately and prevents the FLAMEBLAZER to
produce any high-risk SFX output. As a result, any related hazard/or property
damage is stopped and prevented.
The ARM CONTROLLER is equipped with a key switch to arm/disarm the connected
SFX machine(s), an emergency stop button, and a reset button. The ARM SYSTEM is
wired with EtherCON cables that carry the safety signal from the ARM CONTROLLER.
For more information about the ARM SYSTEM and to learn how to configure a
complete safety system, refer to the ARM SYSTEM Configuration Manual (PART02323).
For more information about the ARM CONTROLLER and to learn how to correctly set
up and use the ARM SYSTEM, refer to the ARM CONTROLLER User and Installation
Manual (PART01882).
1.7
DMX CONTROL
The FLAMEBLAZER is controlled with 1 enable address and 1 operational address:
DMX address
Address range
Control
Enable address
1 - 512
Device enable/disable
Start address
1 - 512
Effect trigger
DMX addresses
The enable address cannot be the same as the operational address. Operating of
these addresses results in the following:
DMX address
DMX Value (decimal) Result
Enable address
0
99
Device disabled
100
154
Device enabled
155
255
Device disabled
Start address
(Effect trigger)
0
199
No output
200
255
Output effect
Operation of the DMX addresses