28 MAGICFX FLAMEBLAZER
®
—
User and Installation Manual
5
Take the necessary safety precautions, including:
a) Creating a safety zone with a distance of 3 m around the effect of the
FLAMEBLAZER and a suitable clearance height depending on nozzle size.
This is calculated by taking the maximum height of the installed nozzle
and adding 50 % safety factor as follows:
•
S nozzle = 9 m (6 m + 50 %);
•
M nozzle = 12 m (8 m + 50 %);
•
L nozzle = 15 m (10 m + 50 %).
b) Making sure that the direct output will be free from persons, animals and
property.
c) Making sure there are no objects near the machine and within the output
distance that can be damaged or catch fire by the emitted heat, flame
and fuel from the FLAMEBLAZER.
3.5
CONNECT THE MACHINE
1.
Install the ARM CONTROLLER in compliance with the instructions from the ARM
CONTROLLER User and Installation Manual (PART01882).
2.
Connect the PowerCon TRUE1 power cable to the power input of the
FLAMEBLAZER. Connect the other end to a 100-250 Vac (50-60 Hz) power
source.
3.
Connect the correct cables between the ARM CONTROLLER, the FLAMEBLAZER,
the control equipment, and other ARM SYSTEM components and machines (if
applicable). Check the following variants for connection details.