22 MAGICFX FLAMEBLAZER
®
—
User and Installation Manual
NOTICE
Ensure the washer seal remains with the nozzle when it is
removed and does not stay in the burn chamber potentially
obstructing the new nozzle from sealing properly.
4
Replace the nozzle that is not needed for the new nozzle and locate it in the
socket of the FLAMEBLAZER Nozzle exchange tool ready for installation, checking
it has a washer seal.
5
Carefully lower the FLAMEBLAZER Nozzle exchange tool with nozzle into the burn
chamber until the nozzle locates into the bulkhead orifice. Rotate anti-clockwise
until a click is heard or felt to check the threads are aligned.
Make sure the tool is held vertical, continuous clockwise rotation will tighten the
nozzle into place.
NOTICE
The nozzle quickly goes from loose to tight as the seal meets the
bulkhead and does not need to be tightened with excessive
force. 12 Nm is sufficient for a good seal.
CAUTION
Check there is no foreign objects or material in the bulkhead
orifice prior to inserting the nozzle as this can lead to blockages
or misfires resulting in a dangerous situation.