MAGICFX FLAMEBLAZER
®
—
User and Installation Manual
31
3.6
FIRE WITH DMX
CAUTION
Wind can influence the effect and cause flames and fuel to divert
off vertical.
1.
Power the machine.
2.
Make sure that the prescribed safety zone is clear and there is a suitable
clearance above the unit for the chosen nozzle.
3.
Set the safety key on the ARM CONTROLLER in the ON position. The pump is
activated and pressurizes the system. The FX LED lights in red, indicating the
system is now armed and the FLAMEBLAZER and other connected SFX machines
are ready to be operated.
4.
Activate the DMX enable address. The FX LED indicator on the machine will flash.
5.
When it’s time to flame, set the DMX value for
Effect trigger
between 200 and 255.
6.
Set the DMX value for
Effect trigger
between 0 and 199 if you want to stop
flaming.
7.
Set the safety key in the OFF position to disarm the ARM SYSTEM and disable
operation of the FLAMEBLAZER and other connected SFX machines.
NOTICE
The maximum continuous duration of the effect is 5 seconds. After
this period the effect will stop automatically. To start the effect
again you must disable and re-enable the
Effect trigger
.
3.7
FIRE WITH PYRO
If pyro is used, follow the next steps:
1.
Power the machine.
2.
Make sure that the prescribed safety zone is clear and there is a suitable
clearance above the unit for the chosen nozzle.
3.
Set the safety key on the ARM CONTROLLER in the ON position. The pump is
activated and pressurizes the system. The FX LED on the FLAMEBLAZER starts
flashing, indicating the system is now armed and the FLAMEBLAZER and other
connected SFX machines are ready to be operated.
4.
When it’s time to flame, turn on a 9-40 Vdc signal from the pyro controller to the
pyro input.
5.
Turn off the 9-40 Vdc signal from the pyro controller if you want to stop flaming.
6.
Set the safety key in the OFF position to disarm the ARM SYSTEM and disable
operation of the FLAMEBLAZER and other connected SFX machines.
NOTICE
The maximum continuous duration of the effect is 5 seconds. After
this period the effect will stop automatically. To start the effect
again you must disable and re-enable the 9-40 Vdc.