30 MAGICFX FLAMEBLAZER
®
—
User and Installation Manual
C
The FLAMEBLAZER is controlled with DMX. The DMX signal and the ARM signal
are combined.
DMX
DMX + ARM
DMX CONTROLLER
ARM CONTROLLER
DMX INJECTOR
BEACON
FLAMEBLAZER
connect another machine
or insert terminator
POWER
4.
If controlled with DMX: Use the display and buttons or a RDM controller to
assign DMX addresses, see Chapter 1.
For more connection and configuration options, refer to the ARM SYSTEM
Configuration Manual (PART02323).
CAUTION
Do not connect more units to a single electrical circuit than the
installed fuse is able to handle. (Calculate the summed load with
the electrical data from Chapter 1)
NOTICE
Insert a TERMINATOR in the last ARM output of each line to close
the safety circuit. The ARM SYSTEM will not work when a line
remains open.
NOTICE
Make sure Pyro Input Control is set to OFF otherwise the DMX
signal LED will not flash, even when there is a DMX signal applied.
NOTICE
When using the pyro Input Control method, make sure Pyro Input
Control is set to ON. The DMX signal LED will not light up.
NOTICE
Always plug in a DMX Terminator into the DMX output of the final
unit in the control sequence. Using a DMX Terminator improves
signal and reliabillity.