14
1.
Remove the 4-20mA/Power plug from the Macurco 6-Series gas detector
2.
Plug the MRS-485 adapter into the empty socket.
3.
Install the provided MRS-485 screw.
4.
See the wiring diagram for wire connection.
Figure 3-9 MRS-485 Installation
3.5.2.1
Connection
The Macurco MRS-485 output is connected via a four-terminal screw type connector. The MRS-485 adapter is wired in the standard 2W-
Modbus circuit definition with selectable built-in terminating resistors at the ends of the RS-485 bus. The power for the MRS-485 adapter
is connected via a two-terminal screw type connector, 12 to 24 VAC or 12 to 24 VDC and no polarity.
Note: Running the Modbus cable adjacent to or in the same conduit with high voltage wires is not recommended as there may be
interference from the high voltages.
Figure 3-10 Modbus Wiring