13
6. Inside the scoreboard, connect the control cable leads to the appropriate terminals on the
terminal block, according to the label above the terminal block.
NOTE: Refer to the connections that were made at the scorekeeper’s location. Make the
connections at the scoreboard match the connections at the scorekeeper’s location.
7. Re-secure the signal/power access door to the scoreboard.
RUNNING & CONNECTING THE ELECTRIC SERVICE
NOTE:
IT IS RECOMMENDED TO HAVE A LICENSED ELECTRICAN RUN THE ELECTRICAL
SERVICE AND CONNECT IT TO THE SCOREBOARD. A WATERTIGHT, NON-FUSIBLE
DISCONNECT SWITCH, A 20-AMP GROUND FAULT INTERRUPTER, AND A SAFETY GROUND
SHOULD BE INSTALLED FOR THE 20-AMP CIRCUIT CONNECTED TO THE SCOREBOARD. A
120-
VOLT CIRCUIT MUST BE AVAILABLE AT THE SCOREKEEPER’S LOCATION FOR THE
CONTROLLER’S 12-VOLT DC WALL TRANSFORMER. IF A BATTERY PACK WAS PURCHASED
WITH THE CONTROLLER, THIS OUTLET BECOMES OPTIONAL.
1.
The scoreboard has a ½” knock-out on the lower right corner for bringing in the electrical
service. It can be enlarged if the conduit size is ¾”. This is where the conduit from the power
source needs to terminate.
2. The connections are standard black, white, and green (ground). Replace the cover when
complete.