HEADER OPERATION - GENERAL
Form 169552 / 169554 / 169555
74
Revision A
6.4 HEADER OPERATION
The M105 Windrower is designed to use the
MacDon A-Series Auger Header, and D50 and
D60 Series Rigid Draper Headers (up to 35 FT),
with or without a Hay Conditioner.
This section describes the attachment and
detachment procedures and operating
instructions for these header types.
6.4.1 HEADER LIFT CYLINDER STOPS
Cylinder stops are located on both header lift
cylinders on the windrower.
To avoid bodily injury or death from fall of raised
header, always engage cylinder stops before
going under header for any reason.
Engage cylinder stops as follows:
a. Press HEADER UP switch to raise header to
maximum height.
NOTE
If one end of the header does not raise
fully, the lift cylinders require re-phasing.
Proceed as follows:
1. Press and hold HEADER UP switch until
both cylinders stop moving.
2. Continue to hold switch for 3 - 4 seconds.
3. Cylinders are phased.
b. Pull lever (A), and rotate toward header to
release, and lower cylinder stop (B) onto
cylinder. Repeat for both lift cylinders.
c. To store, turn lever (A) away from header to
raise cylinder stop until lever locks into vertical
position.
HEADER UP
HEADER DOWN
B
A