7.  Maintenance

7.1 

Cleaning the ET750 and the ET650

Only use a soft cloth and neutral detergents to clean 
the housing and display of the ET750 and the ET650. 
Do not use abrasive cleaning agents and coarse 
workshop cloths!

7.2 

Maintenance

In the DDC 

Customer service

 tab, various tests can 

be performed for the ET650. Some of these tests can 
only be performed by customer service. 

7.3 

Storage battery replacement

WARNING - Risk of explosion on charging 
battery!

Risk of explosion and hence burns 
and injury when charging the battery 
improperly!

 

Only use the storage battery specified for 
the ET750.

 

Only use the power supply unit specified 
for the ET750.

 

Heed the notes on disposal. 

 

Storage battery must not be heated, 
burnt, short-circuited, mechanically 
damaged and charged with excessively 
high currents or reverse polarity!

 

Suitable extinguishing agents: water, 
CO

2

, sand.

1. 

Switch off the ET750.

2. 

Loosen the screws in the battery cover (fig. 3, 
item 1) on the back of the ET750 and remove the 
battery cover (fig. 3, item 2).

3. 

Loosen the screws on the storage battery (fig. 7, 
item 1).

4. 

Remove the storage battery.

5. 

Place a new storage battery in the battery 
compartment and slide it onto the battery 
connector.

6. 

Fasten the storage battery using the two screws on 
the battery.

7. 

Reinstall the battery cover and fasten it with the 
screws.

8. 

Switch on the ET750.

 

i

The storage battery charge indicator can be called 
up via the 

 icon. 

 

"

The storage battery charge indicator shows the 
current battery charge on a scale of 0 to 100 %. 

 

i

It is advisable to charge the battery for at least three 
hours before running the ET750 off the battery.

7.4 

Recovery process WIN 10

 

!

All data and programs on the hard disk will be 
erased during the recovery process.

1. 

Connect the ET750 to the power supply unit.

2. 

Insert the SD memory card (recovery) in the 
memory card slot of the ET750(Fig. 2, item 4).

3. 

Connect the USB keyboard to the ET750.

4. 

Switch on the ET750.

5. 

Press <

ESC

> on the USB keyboard.

 

After 5 seconds the boot menu "

Front page

" is 

opened.

6. 

Select "

Boot Manager

" with 

u

.

7. 

Press 

E

.

8. 

Select "

SDC

" with 

u

.

9. 

Press 

E

.

 

The following message is displayed: 

Press any 

key to boot from USB.

 

Press any key within 5 seconds.

 

The boot process is started.

 

The following message is displayed: 

Would you 

really want to recover your computer?

10. Confirm <

Yes

> with 

E

.

11. The following message is displayed: 

WARNING! ALL 

DATA ON HARD DISK DRIVE C: WILL BE LOST. 

Please be patient while recovery process 

is running. Proceed with recovering?

 

12. 

Confirm <

Yes

> with 

E

.

 

ET750 Recovery is started, duration approx. 
40 minutes.

13. 

The following message is displayed: 

Press 

any key to continue..

14. 

Remove the SD memory card.

15. 

Press 

E

.

 

The ET750 is switched off.

16. 

Switch on the ET750.

 

Windows is re-started.

 

After approx. 5 minutes the window "

Hi there

" is 

displayed.

17. 

Configure the operating system (see sec. 5.3).

18. 

Remove the USB Keyboard.

 

"

This completes the recovery process.

 

i

Then, install the HUB again via the SD memory card 
and follow the instructions on the screen.

Summary of Contents for Mentor Touch ET750

Page 1: ...ET750 en Operating instructions Diagnostic System ET750 ET650...

Page 2: ......

Page 3: ...l unit diagnosis 13 4 6 2 Firmware update 13 5 Initial commissioning 13 5 1 Fitting the storage battery 13 5 2 Connection 13 6 Operation ET750 14 6 1 Switching on the ET750 14 6 2 Switching off the ET...

Page 4: ...ices also indicate the consequences of the hazard as well as preventive action Warning notices have the following structure Warning symbol KEY WORD Nature and source of hazard Consequences of hazard i...

Page 5: ...ational agreements and other national legal regulations Copying or selling of data and software or any part thereof is impermissible and punishable in the event of any infringements Bosch reserves the...

Page 6: ...uipment and operating material is operated in keeping with electrical engineering principles If a piece of electrical equipment or operating material is found to be defective i e it does not or no lon...

Page 7: ...es Make sure that all test connections are properly plugged in and secure Before disconnecting the B cable from the engine ground or battery B switch off the ignition Never open the enclosures 3 1 2 H...

Page 8: ...ries and rechargeable batteries avoid getting it on your skin or in your eyes Rules of conduct If contact with skin or eyes happens nevertheless wash the affected parts immediately with clean water an...

Page 9: ...lways ensure effective ventilation and suction when working in closed areas 3 6 Danger of asphyxiation Car exhaust fumes contain carbon monoxide CO a colorless odorless gas If inhaled carbon monoxide...

Page 10: ...e g read DTCs display actual values activate actuators use other specific control unit functions ET750 may only be operated with the storage battery of Robert Bosch GmbH Model 2ICR18 65 2 and the powe...

Page 11: ...and switches off the ET750 i i Pressing the On Off button for 5 seconds switches off the ET750 without first shutting down the operating system This mode should only be used if shutdown of the Windows...

Page 12: ...ot present Check power supply Flashes green 1 second interval ET650 ready for operation None Illuminated green Fault in hardware Firmware Flashes yellow 1 second interval Overvoltage on diagnostic cab...

Page 13: ...upply the ET650 using the provided power supply unit and connect to ET750 using the USB connecting cable Do not interrupt the USB connection during the firmware update The firmware update can also be...

Page 14: ...r options The menu Start Control panel Power options can be used to select and alter the power plan e g the monitor switch off time or the display brightness setting 5 3 Configuration of the operating...

Page 15: ...The ET750 features a virtual keypad Pressing the icon in the task bar or pressing the function key for 2 seconds opens or closes the on screen keyboard as applicable The on screen keyboard functions...

Page 16: ...ng a HUB update installation always supply the ET750 with voltage by way of the power supply unit The further update installation procedure is described in detail in the HUB online help 6 13 Informati...

Page 17: ...gain This switch off procedure is only to be employed if the ET750 will not react to any key being pressed as it may result in loss of data on the hard disk if it is implemented during regular operati...

Page 18: ...tery charge indicator can be called up via the icon The storage battery charge indicator shows the current battery charge on a scale of 0 to 100 i i It is advisable to charge the battery for at least...

Page 19: ...1 684 461 186 Power supply cable en S P03 100 647 Stylus 3 pc 1 687 010 403 SD memory card SW Recovery Windows 10 Enterprise 2016 LTSB 1 688 400 635 SD memory card SW Recovery Windows 10 Enterprise 2...

Page 20: ...rd disk 256 GB SSD WLAN WLAN 802 11 b g n Bluetooth Bluetooth 2 1 Class 1 Storage battery Li ion 7 26 V 5200 mAh Dimensions H x W x D 249 x 329 x 53 mm 9 8 x 12 9 x 2 1 inch Weight with storage batter...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...Robert Bosch GmbH Automotive Service Solutions Franz Oechsle Stra e 4 73207 Plochingen DEUTSCHLAND www bosch com bosch prueftechnik bosch com 1 689 989 285 2020 02 24...

Reviews: