background image

1 689 989 285

2020-02-24

Robert Bosch GmbH

Initial commissioning  |  ET750  |  13

en

4.6.1 

Notes on control unit diagnosis 

The ET650 is supplied with voltage either via the 
power supply unit provided or the OBD interface in the 
vehicle.

 

!

If a test step involves starting the engine, the 
battery voltage may drop to such an extent that 
supply via the vehicle is no longer guaranteed. In 
such cases it may be necessary to run the ET650 by 
way of the power supply unit.

 

i

On some vehicles, the ignition must be switched on 
for power to be supplied via the OBD interface.

Connection to the diagnostic interface in the vehicle is 
done using the OBD connection cable (fig. 6, item. 2).

 

!

Make sure the OBD connection cable is properly 
connected to the ET650. Incorrect connection 
could cause the pins of the plug to bend or break 
off. Only use the OBD connection cable contained 
in the scope of delivery of the ET750.

 

i

Notes on control unit diagnosis can be found in the 
online help for the HUB software (

).

4.6.2 

Firmware update

After an

 

update of HUB, the firmware of the ET650 is 

updated automatically when the control unit diagnosis 
is started. 
To update the firmware, supply the ET650 using 
the provided power supply unit and connect to 
ET750 using the USB connecting cable. Do not 
interrupt the USB connection during the firmware 
update. The firmware update can also be done using 
DDC (Diagnostic Device Configuration) (see online 
help on DDC).

 

!

For the ET650, firmware updates must always be 
performed using the USB connecting cable (not by 
way of Bluetooth).

5.  Initial commissioning

 

Remove the ET750, the ET650, the storage battery 
and the power supply unit with power supply cable 
from the case.

5.1 

Fitting the storage battery

1. 

Loosen the screws in the battery cover (fig. 3, item 1) 
on the back of the ET750 and remove the battery 
cover.

2. 

Orient the storage battery properly, place it in the 
battery compartment (fig. 7, item 2) and slide it 
onto the battery connector (fig. 7, item 3).

3. 

Fasten the storage battery using the two screws on 
the battery.

4. 

Reinstall the battery cover and fasten it with the 
screws.

459966-06_Re

1

3

1

2

Fig. 7: 

Inserting the storage battery

1  Battery fastening sleeves
2  Battery compartment
3  Battery connector

 

i

It is advisable to charge the storage battery for at 
least three hours before running the ET750 off the 
battery.

5.2 

Connection

Prior to the initial commissioning, make sure the 
mains voltage coincides with the voltage specified on 
the power supply unit (use the power supply cable 
provided).

Summary of Contents for Mentor Touch ET750

Page 1: ...ET750 en Operating instructions Diagnostic System ET750 ET650...

Page 2: ......

Page 3: ...l unit diagnosis 13 4 6 2 Firmware update 13 5 Initial commissioning 13 5 1 Fitting the storage battery 13 5 2 Connection 13 6 Operation ET750 14 6 1 Switching on the ET750 14 6 2 Switching off the ET...

Page 4: ...ices also indicate the consequences of the hazard as well as preventive action Warning notices have the following structure Warning symbol KEY WORD Nature and source of hazard Consequences of hazard i...

Page 5: ...ational agreements and other national legal regulations Copying or selling of data and software or any part thereof is impermissible and punishable in the event of any infringements Bosch reserves the...

Page 6: ...uipment and operating material is operated in keeping with electrical engineering principles If a piece of electrical equipment or operating material is found to be defective i e it does not or no lon...

Page 7: ...es Make sure that all test connections are properly plugged in and secure Before disconnecting the B cable from the engine ground or battery B switch off the ignition Never open the enclosures 3 1 2 H...

Page 8: ...ries and rechargeable batteries avoid getting it on your skin or in your eyes Rules of conduct If contact with skin or eyes happens nevertheless wash the affected parts immediately with clean water an...

Page 9: ...lways ensure effective ventilation and suction when working in closed areas 3 6 Danger of asphyxiation Car exhaust fumes contain carbon monoxide CO a colorless odorless gas If inhaled carbon monoxide...

Page 10: ...e g read DTCs display actual values activate actuators use other specific control unit functions ET750 may only be operated with the storage battery of Robert Bosch GmbH Model 2ICR18 65 2 and the powe...

Page 11: ...and switches off the ET750 i i Pressing the On Off button for 5 seconds switches off the ET750 without first shutting down the operating system This mode should only be used if shutdown of the Windows...

Page 12: ...ot present Check power supply Flashes green 1 second interval ET650 ready for operation None Illuminated green Fault in hardware Firmware Flashes yellow 1 second interval Overvoltage on diagnostic cab...

Page 13: ...upply the ET650 using the provided power supply unit and connect to ET750 using the USB connecting cable Do not interrupt the USB connection during the firmware update The firmware update can also be...

Page 14: ...r options The menu Start Control panel Power options can be used to select and alter the power plan e g the monitor switch off time or the display brightness setting 5 3 Configuration of the operating...

Page 15: ...The ET750 features a virtual keypad Pressing the icon in the task bar or pressing the function key for 2 seconds opens or closes the on screen keyboard as applicable The on screen keyboard functions...

Page 16: ...ng a HUB update installation always supply the ET750 with voltage by way of the power supply unit The further update installation procedure is described in detail in the HUB online help 6 13 Informati...

Page 17: ...gain This switch off procedure is only to be employed if the ET750 will not react to any key being pressed as it may result in loss of data on the hard disk if it is implemented during regular operati...

Page 18: ...tery charge indicator can be called up via the icon The storage battery charge indicator shows the current battery charge on a scale of 0 to 100 i i It is advisable to charge the battery for at least...

Page 19: ...1 684 461 186 Power supply cable en S P03 100 647 Stylus 3 pc 1 687 010 403 SD memory card SW Recovery Windows 10 Enterprise 2016 LTSB 1 688 400 635 SD memory card SW Recovery Windows 10 Enterprise 2...

Page 20: ...rd disk 256 GB SSD WLAN WLAN 802 11 b g n Bluetooth Bluetooth 2 1 Class 1 Storage battery Li ion 7 26 V 5200 mAh Dimensions H x W x D 249 x 329 x 53 mm 9 8 x 12 9 x 2 1 inch Weight with storage batter...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...Robert Bosch GmbH Automotive Service Solutions Franz Oechsle Stra e 4 73207 Plochingen DEUTSCHLAND www bosch com bosch prueftechnik bosch com 1 689 989 285 2020 02 24...

Reviews: