3.  Safety instructions

3.1 

Risk of electric shocks

3.1.1 

Low voltages, high voltages

Hazardous voltages occur in both the lighting 
system and the electrical system of a motor 
vehicle. If contact is made with live parts 
(e.g. with the ignition coil), there is a risk of 
electric shock from flashover voltages caused 
by damaged insulation (e.g. ignition cables 
which have been attacked by martens). These 
apply to the secondary and primary sides of 
the ignition system, the wiring harness with 
connectors, lighting system (Litronic) as well 
as connection to the vehicle.

Safety measures:

 

Only  connect to a properly grounded outlet.

 

Only the enclosed or a tested power supply cable is 
to be used.

 

All extension cables must be fitted with shock-proof 
contacts.

 

Do not exceed the voltage limits as specified on the 
connection cables.

 

Any cables with damaged insulation must be 
replaced.

 

Check the electrical equipment every two years and 
immediately deal with any problems.

 

Only use fuses with specified current ratings.

 

Before connecting it to the vehicle, first connect the 
product to the lighting mains and switch on.

 

Before switching on the ignition connect the (B-) 
cable to engine ground or the battery (B–) terminal.

 

Always switch off the ignition before performing 
any work on the electrical system of the vehicle. 
Intervention includes, for instance, connection to the 
vehicle, replacement of ignition system components, 
removal of equipment (e. g. alternators), connection 
of equipment to a test bench.

 

Wherever possible, tests and settings should always 
be caried out with the ignition switched off and the 
engine stationary.

 

If tests or settings are carried out with the ignition 
switched on or the engine running, care must be 
taken not to touch any live parts. This applies 
to all connection cables and leads as well as to 
connections of equipment to test benches.

 

Test connections must always be made using 
suitable connectors (e.g. Bosch testing cable set or 
vehicle-specific adapter cables).

 

Make sure that all test connections are properly 
plugged in and secure.

 

Before disconnecting the (B-) cable from the engine 
ground or battery (B–), switch off the ignition.

 

Never open the enclosures.

3.1.2 

High voltages in hybrid vehicles and electric 
vehicles as well as their high-voltage 
components

If high-voltage components or high-voltage 
wires are inexpertly handled, there is a risk 
of fatal injury from high voltages and the 
possible transmission of current through the 
body.

 

Deenergization is only to be performed 
by a qualified electrician, a qualified 
electrician for specific tasks (hybrid) or a 
power systems engineer. 

 

Work on vehicles with high-voltage 
components is only ever to be performed 
in a safe, deenergized condition by 
persons with the minimum qualification 
"Trained to perform electrical work". 

 

Even after deactivating the high-voltage 
vehicle electrical system, the high-voltage 
battery may still be live.

 

Operating condition cannot be established 
from any running noise, as the electric 
machine is silent when stationary.

 

In gear positions "P" and "N" the engine 
or electric motor may start spontaneously 
depending on the charge of the high-voltage 
battery.

Safety measures:

 

Never open or damage high-voltage batteries.

 

On accident vehicles, never touch high-voltage 
components or exposed high-voltage wires before 
deactivating the high-voltage vehicle electrical 
system.

 

Avoid contact with any high-voltage components 
and high-voltage wires (orange sheathing) when in 
operation.

 

Secure against unauthorized renewed start-up  
(e.g. by means of a padlock).

 

After each switch off of the high-voltage system, 
observe a waiting time of 5 minutes (depending 
on the manufacturer's instructions). Subsequently 
ascertain the absence of voltage using a suitable 
testing device.

 

Visually inspect the high-voltage components and 
high-voltage wires for damage. The power systems 
engineer responsible should always be immediately 
notified of any irregularities, doubts or defects 
found.

 

$

High-voltage components must never exhibit 
signs of external damage.

 

$

The insulation of the high-voltage wiring must 
be intact and undamaged.

 

$

Watch out for any abnormal deformation of the 
high-voltage wiring.

Safety instructions  |  ET750  |  7

en

Summary of Contents for Mentor Touch ET750

Page 1: ...ET750 en Operating instructions Diagnostic System ET750 ET650...

Page 2: ......

Page 3: ...l unit diagnosis 13 4 6 2 Firmware update 13 5 Initial commissioning 13 5 1 Fitting the storage battery 13 5 2 Connection 13 6 Operation ET750 14 6 1 Switching on the ET750 14 6 2 Switching off the ET...

Page 4: ...ices also indicate the consequences of the hazard as well as preventive action Warning notices have the following structure Warning symbol KEY WORD Nature and source of hazard Consequences of hazard i...

Page 5: ...ational agreements and other national legal regulations Copying or selling of data and software or any part thereof is impermissible and punishable in the event of any infringements Bosch reserves the...

Page 6: ...uipment and operating material is operated in keeping with electrical engineering principles If a piece of electrical equipment or operating material is found to be defective i e it does not or no lon...

Page 7: ...es Make sure that all test connections are properly plugged in and secure Before disconnecting the B cable from the engine ground or battery B switch off the ignition Never open the enclosures 3 1 2 H...

Page 8: ...ries and rechargeable batteries avoid getting it on your skin or in your eyes Rules of conduct If contact with skin or eyes happens nevertheless wash the affected parts immediately with clean water an...

Page 9: ...lways ensure effective ventilation and suction when working in closed areas 3 6 Danger of asphyxiation Car exhaust fumes contain carbon monoxide CO a colorless odorless gas If inhaled carbon monoxide...

Page 10: ...e g read DTCs display actual values activate actuators use other specific control unit functions ET750 may only be operated with the storage battery of Robert Bosch GmbH Model 2ICR18 65 2 and the powe...

Page 11: ...and switches off the ET750 i i Pressing the On Off button for 5 seconds switches off the ET750 without first shutting down the operating system This mode should only be used if shutdown of the Windows...

Page 12: ...ot present Check power supply Flashes green 1 second interval ET650 ready for operation None Illuminated green Fault in hardware Firmware Flashes yellow 1 second interval Overvoltage on diagnostic cab...

Page 13: ...upply the ET650 using the provided power supply unit and connect to ET750 using the USB connecting cable Do not interrupt the USB connection during the firmware update The firmware update can also be...

Page 14: ...r options The menu Start Control panel Power options can be used to select and alter the power plan e g the monitor switch off time or the display brightness setting 5 3 Configuration of the operating...

Page 15: ...The ET750 features a virtual keypad Pressing the icon in the task bar or pressing the function key for 2 seconds opens or closes the on screen keyboard as applicable The on screen keyboard functions...

Page 16: ...ng a HUB update installation always supply the ET750 with voltage by way of the power supply unit The further update installation procedure is described in detail in the HUB online help 6 13 Informati...

Page 17: ...gain This switch off procedure is only to be employed if the ET750 will not react to any key being pressed as it may result in loss of data on the hard disk if it is implemented during regular operati...

Page 18: ...tery charge indicator can be called up via the icon The storage battery charge indicator shows the current battery charge on a scale of 0 to 100 i i It is advisable to charge the battery for at least...

Page 19: ...1 684 461 186 Power supply cable en S P03 100 647 Stylus 3 pc 1 687 010 403 SD memory card SW Recovery Windows 10 Enterprise 2016 LTSB 1 688 400 635 SD memory card SW Recovery Windows 10 Enterprise 2...

Page 20: ...rd disk 256 GB SSD WLAN WLAN 802 11 b g n Bluetooth Bluetooth 2 1 Class 1 Storage battery Li ion 7 26 V 5200 mAh Dimensions H x W x D 249 x 329 x 53 mm 9 8 x 12 9 x 2 1 inch Weight with storage batter...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...Robert Bosch GmbH Automotive Service Solutions Franz Oechsle Stra e 4 73207 Plochingen DEUTSCHLAND www bosch com bosch prueftechnik bosch com 1 689 989 285 2020 02 24...