COMPONENT IDENTIFICATION

 HOW TO OPEN THE COVER WHEN SETTING DIP SW

Hold at the top and bottom of the unit as shown below and 

slide the housing cover gently to open until it hits the latch-
ing inside the unit.

 HOW TO SEPARATE THE EURO TYPE CONNECTOR     

TERMINAL BLOCKS

When you need to separate the euro type connector termi

-

nal blocks from the transmitter body for wiring, insert a mi-
nus driver between the euro type connector terminal block 
and the housing body, pull up the driver and pull out the 
euro type connector terminal block.

INSTALLATION

 DIN RAIL MOUNTING

Set the unit so that its DIN rail adaptor is at the bottom.  

Position the upper hook at the rear side of the unit on the 

DIN rail and push in the lower.  When removing the unit, 
push  down  the  DIN  rail  adaptor  utilizing  a  minus  screw

-

driver and pull.

Body

SW Setting

Specifications
(side)

• Housing Cover Fully Opened

Caution: 
Handle the cover carefully to protect internal components from damage.
DO NOT pull beyond where the housing cover is latched.  The plastic 
housing may be damaged.

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

Summary of Contents for M3LPA2

Page 1: ...unted inside a panel Insert noise filters for the power source connected to the unit Densei Lambda Model MBS 1220 22 or equivalent is recommended The actual installation environments such as panel con...

Page 2: ...insert a mi nus driver between the euro type connector terminal block and the housing body pull up the driver and pull out the euro type connector terminal block INSTALLATION DIN RAIL MOUNTING Set th...

Page 3: ...NPUT External DC Supply DC POWERED TYPE 2 Be aware that the AC power and DC power connect to different terminals 2 DC POWER INPUT 1 U V 1 3 2 6 5 4 CONFIGURATOR JACK 7 8 10 12 OUTPUT AC POWERED TYPE 2...

Page 4: ...d the pulse sensing type and noise filter must be selected with the DIP SW4 1 through SW4 3 See Tables 9 and 10 For detailed information on the PC configuration refer to the M3LPACFG instruction manua...

Page 5: ...h the large noise filter setting and to 10 msec with the small noise filter setting OUTPUT TYPE SW3 1 Table 11 OUTPUT SW3 3 SW3 2 SW1 4 SW1 3 SW1 2 SW1 1 0 20mA OFF ON OFF ON OFF OFF 2 5 2 5V ON OFF O...

Page 6: ...ght is ON and the LD2 red light is blinking 5 0 Input Ranging Apply the desired minimum input level e g 10 Hz from the simulator and push DOWN button until the LD1 flashes for approx 5 sec and then tu...

Page 7: ...A the green LED is blinking For the model M3LPA2 x B the green LED turns on In order to change the threshold apply simulated 100 input signal and push UP increase or DOWN decrease buttons until the ou...

Page 8: ...explained below Both zero and span are adjustable within 15 1 Run Mode Confirm that the green LED is blinking model M3LPA2 x A or the green LED turns on model M3LPA2 x B 2 Fine Zero Calibration Mode...

Page 9: ...VITY SCALE 50 100V p p 1 20 25 50V p p 1 10 10 25V p p 1 5 5 10V p p 1 2 1 5V p p 1 0 5 1V p p 1 0 1 0 5V p p 1 A specific sensitivity scale is applied according to the pulse amplitude by setting up t...

Page 10: ...operating conditions DIP SW Configuration RUN Mode The transmitter is configured via DIP SW and is in normal operating conditions Output Saturated in PC Configuration Mode Option A The output is satur...

Reviews: