C.
XY TILT CALIBRATION
NOTE: To be performed only for specific manufacturing situations, not used otherwise
Objective: To manually compensate (post calibration*) residual bed tilt errors.
Tool: X-Y Tilt Compensation module
Use this tool to orient the Z axis so that it is perpendicular to the build surface. This will ensure that
material is deposited in a regular and uniform manner on the build plate.
To access this tool:
WebControl>Settings>calibration
To enter a value (Press
“
Enter
”
to validate)
To adjust the value in increments of 0.01°
or %
To modify the tilt displayed in ° or %
% value = Z distance for 100 mm of X or Y
offset