Charging the Main Battery Pack
47
E-EQ-MX6PCRG-C-ARC
MX6 PPC Reference Guide
Charging the Main Battery Pack
Using the Four Bay Charger/Analyzer (Optional)
Note: The Multicharger must be connected to an AC/DC power source before battery charging
can occur. The multicharger accepts main battery packs used by all MX6 mobile devices.
Figure 3-9 MX6 Multicharger
See Also:
Appendix C “MX6 Multicharger”.
The four bay Multicharger has four slots that fully charge a main battery in four hours. The
charging slots work independently to control the charging of individual battery packs.
The last slot on the right also functions as a battery analyzer/charger. It resets and re-calibrates a
battery, then displays it’s resulting capacity. The process monitors changes in temperature,
current, and voltage. The slot senses when a battery pack is fully charged and automatically
switches to maintain the battery at full capacity indefinitely.
How To Charge a Spare Battery Pack
1.
Insert the end of the battery without the locking tab into the charging slot.
2.
Snap the battery into place with a hinging motion.
3.
Once the battery is inserted, observe the Status LED to monitor the charging process.
The Status LED is orange while the battery is charging, and green when the charge cycle is
complete.
How To Charge/Analyze a Spare Battery Pack
1.
Insert the end of the battery without the locking tab into the right hand charge/analyze slot.
2.
Snap the battery into place with a hinging motion.
3.
Once the battery is inserted, press the Analyze button. Observe the Indicator LEDs to monitor
the charge/analyze process.
The Status LED flashes orange during the analyze phase, illuminates solid green when the analyze
cycle has completed. When the cycle is complete, the Indicator LEDs display the current battery