4-12
User Manual CM-CAN1
4 Setting the device parameters
unit must not be switched off, otherwise the settings will be lost. Parame-
ter 150-SAVE is automatically set to 0 by the device after the save opera-
tion. This process can be used for timeout monitoring of the function.
4.4
Representation
of parameter
number
The parameter number (PARA_HI PARA_LO) is represented as a four-
digit hexadecimal number.
Drive units have parameter numbers from 0 - 999. These parameters
must be converted to four-digit hexadecimal numbers and inserted into
the protocol frame under PARA_HI and PARA_LO, with PARA_LO repre-
senting the Low Byte and PARA_HI the High Byte of the parameter num-
ber (see section 4.1 and 4.6). Leading zeroes must be entered.
Subject area
Value range
Factory set.
Unit
Data type
Memory type
_15FC
0 (STOP) ...
1 (START)
0 (STOP)
–
USIGN8
RAM control
value