In the case you need to reset the unit without the web interface or Araneo, the GigaCore 30i offers different
levels of reset, based on the ones you can find in the web interface or Araneo.
Reset
: The unit is brought back to its default configuration, with the default IP address that can be found
on the rear of the device or on the E-ink display. Profiles stored in the device are preserved.
Default login: admin
Default password: No password
Reload Defaults
: The profile stored in slot one is reloaded. The “Reload Default” is available only if the
profile stored in slot one has been locked through the utility menu. If this profile is set with a password,
then the user will need to enter it through the web interface to access the switch’s menu.
Default login: admin
Default password: No password
Factory Reset
: With a factory reset the device is fully reset to the state it left Luminex and ALL data will
be erased.
Default login: admin
Default password: No password
RESETTING THE DEVICE WITH THE MODE BUTTON IS AVAILABLE IF THE MODE BUTTON HAS NOT
BEEN DISABLED IN DEVICE SETTINGS OR, IF DISABLED IN DEVICE SETTINGS, WITHIN 2 MINUTES
AFTER BOOTING THE SWITCH.
The different reset options in more detail:
4.1 reset
Condition 1: The device is currently running.
Condition 2: There is no profile set as default profile.
Hold the mode button for at least five seconds until the four status LEDs are flashing red. Releasing the
mode button whilst the status LEDs are flashing will reset the unit.
Be aware, releasing the mode button before the status LEDs start flashing red, or after the LEDs have
stopped flashing red, will cancel the operation.
5s
5s
5s
Timing
Hold the mode button
Release the button = Reset
Release the button = Cancel
Function
Ok
Power RLinkX PoE
Mode
Ok
Power RLinkX PoE
Ok
Power
RLinkX PoE
Ok
Power
RLinkX
PoE
Ok
Power RLinkX
PoE
28