Chapter 10 Diagnostic Function
10-9
10.4.2 View error details
The detail information on the errors in the frames which are transmitted from or received by RAPIEnet I/F Modules can
be viewed.
In the contents of the packet monitoring in the media information window, if the error count is 1 or more, the View Error
Detail button on the bottom window is activated. Click this button to open the Detail Packet Monitoring window. In this
window, number of the error packets for each port and each error can be checked.
Items
Description
Tx_Retry_Over Cnt
No. of the frames failed to be transmitted by 16 times of
transmission
Delay Collision Detect Cnt
No. of the delay conflicts occurred in the line after transmission
Lost Carrier Cnt
No. of carrier lost occurred in the transmission
Carrier Not Detected Cnt
No. of failures to detect carrier during preamble transmission
CRC Error Frame Receive Cnt
No. of frame occurrence for which CRC error was received
Frame Receive Error Cnt
No. of frames where reception error occurred
Too-Short Frame Cnt
No. of received frames less than 64 bytes
Too-Long Frame Cnt
No. of received frames larger than 1518 bytes
Residual-Bit Frame Cnt
No. of received frames including Residual-Bit
Multicast Addr Frame Receive Cnt
No. of received frames having multi-cast addresses